LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> PLC Q25HCPU Structured Text(ST) Programming Guide Book MITSUBISHI Q25HCPU Manual

PLC Q25HCPU Structured Text(ST) Programming Guide Book MITSUBISHI Q25HCPU Manual

Product model: Q25HCPU
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text(ST) Programming Guide Book
File language: English
File size: 1.23MB
8 slots.
Extended substrate.
Double power supply mode power supply redundancy system.
Used to install Q series modules.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc Q25HCPU Programming Guide Book. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance Q25HCPU
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Wider application range, more advanced.
Leading in the era of the Q series CPU products Q25HCPU Programming Guide Book.
Q series CPU products a wide range of applications,
Provide programmable controller, process, redundancy, C language, movement, manipulator, CNC all kinds of CPU,
In order to meet the needs of various control.
Through the multi CPU configuration, can be based on the use of the scale, purpose,
Construction of the best system to meet the requirements of all kinds of control.
In addition, the high reliability system can be constructed by the redundant system,
Even if a fault occurs, the system can continue to run Q25HCPU Programming Guide Book. Input: 4 channels.
Platinum resistance (Pt100; JPt100).
No heater disconnection detection function MITSUBISHI Q25HCPU Manual.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost MITSUBISHI Q25HCPU Manual.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs MITSUBISHI Q25HCPU Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperrature regulating module has the function of preventing overheating and preventing over cooling Q25HCPU Structured Text(ST).
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode Q25HCPU Programming Guide Book.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Related products
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
Programmable logic controller CPU
R16ENCPU
MITSUBISHI Programmable logic controller CPU R16ENCPU
Operation control mode: stored procedure repe
MITSUBISHI
Moving CPU unit
A73CPU
MITSUBISHI Moving CPU unit A73CPU
Multi axis positioning controller. Program ca