Product model: CJ1W-PTS15
Name: Programmable Controllers
Brand: OMRON
Sort: Safety Precautions
File language: English
File size: 0.34MB
Specification: 32 output points.Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: Set separately for each input.
Signal range; Resolution: 1 to 5 V (1/10,000),
0 to 10 V (1/20,000), -5 to 5 V (1/20,000),
-10 to 10 V (1/40,000), and 4 to 20 mA (1/10,000) CJ1W-PTS15 Manual.
Conversion period: 20 μs/1 point, 25 μs/2 points,
30 μs/3 points, 35 μs/4 points,
The Direct conversion is provided CJ1W-PTS15
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.4% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 24V, --.
Standards: UC1, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup CJ1W-PTS15 Manual.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals.

Output method: Transistor sourcing.
Inputs: ---.
Outputs: 8.Model: C200H-MD115.
No. of I/O pts: 16 inputs, 16 outputs.
Specifications: 12VDC.Analog inputs: 4 points CJ1W-PTS15 Manual. Model: C500-CN512N.
Cable length 50cm.
CV Series C Series Expansion ← → I / O device CPU Connecting cable(Vertical-wired)Name: e-CON Connectors.
Specifications: Inputs/Outputs;
16 inputs /16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection OMRON CJ1W-PTS15 Safety Precautions.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced OMRON CJ1W-PTS15 Safety Precautions.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON CJ1W-PTS15 Safety Precautions. Product name: CJ1M CPU Units; built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
160 points/10 Units (No Expansion RRack); Program capacity,
5K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0 CJ1W-PTS15 . 1 μs;
Built-in I/O , 10 inputs and6 outputs,
2 counter inputs, 2 pulse outputs.
Current consumptioon: 5v, 0 CJ1W-PTS15 Manual. 64A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry.
Related products
OMRON
DeviceNet Unit
CJ1W-DRM21
OMRON DeviceNet Unit CJ1W-DRM21
Unit classification: CJ1 CPU Bus Unit. Spec
OMRON
Temperature Control Unit
CJ1W-TC004
OMRON Temperature Control Unit CJ1W-TC004
Unit classification: CJ1 Special I/O Units.
OMRON
Process Analog I/O Unit
CJ1W-PTS16
OMRON Process Analog I/O Unit CJ1W-PTS16
Unit classification: CJ1 Special I/O Units.
OMRON
Process Analog I/O Unit
CJ1W-PTS15
OMRON Process Analog I/O Unit CJ1W-PTS15
Unit classification: CJ1 Special I/O Units.