Output points: 32 points.
Output voltage and current: DC5 ~ 24V0.2A/1 point.
2A/1 common end.
Response time: 2 s; 32 1 public end leakage.
40 pin connector.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password MITSUBISHI PLC Programming Manual
Q02HCPU-A
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location MITSUBISHI PLC Programming Manual.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields MITSUBISHI PLC Programming Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q02HCPU-A Programming Manual. And there is no need to select the cable, the straight line and the cross line can be used Q02HCPU-A Programming Manual.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.5 slots; requires 1 AnS series PLC power modules;
Used to install large AnS series PLC module.
Base plate of AnS series PLC Q02HCPU-A Programming Manual.
QA1S series PLC 5 slot main substrate.
AnS series of modules can be installed. Input points: 16 points.
Input voltage and current: 4mA AC48V/DC48V.
Response time: 20ms.
16 point /1 a public side.
Positive / negative common.
18 point terminal station.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password Q02HCPU-A Manual .
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorizeed access to unauthorized users MITSUBISHI PLC Programming Manual.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.