Upgrade payments.
Input / output points: 256 points.
Program capacity: 8 K step.
Processing speed: 0.2 s.
Built in communication port: RS232*1.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password MITSUBISHI Q170MCPU-S1 Manual
Q170MCPU-S1
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
CPU module expansion standard RAM (max 8MB) MITSUBISHI Q170MCPU-S1 Manual.
Can be used with the SD memory card at the same time.
Continuous access file register.Compact flash memory card.
Capacity: 512M bytes. PCI bus /PCI-X bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
With external power supply function.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) MITSUBISHI Q170MCPU-S1 Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stationns, the length of the total cable length, strong anti-interference Q170MCPU-S1 Reference Manual.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system Q170MCPU-S1 Reference Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.