Appearance: M12.
Sensing distance: 8 mm.
Connection method: M12 Connector Models .
Cable specifications: --.
Polarity: Yes.
Operation mode : NC.
Pin arrangement: 1: +V, 2: 0 V.
Applicable connector code: D.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E E2E-C03N02-CJ-C1 INSTRUCTION sheet.
Standard Sensors for detecting ferrous metals
E2E-C03N02-CJ-C1
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection E2E-C03N02-CJ-C1 INSTRUCTION sheet.
Cable protector provided as a standard feature. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E2E-C03N02-CJ-C1 INSTRUCTION sheet.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E2E-C03N02-CJ-C1 Manual. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling OMRON E2E-C03N02-CJ-C1 Manual.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance OMRON E2E-C03N02-CJ-C1 Manual. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Coontroller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2E-C03N02-CJ-C1 .
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E2E-C03N02-CJ-C1 INSTRUCTION sheet.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.