Actuator: Plunger.
Conduit openings: M20.
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts D4NH-2DAS INSTRUCTION sheet.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever D4NH-2DAS
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13) D4NH-2DAS INSTRUCTION sheet.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Type: Welding / wire type, with left column.
Drive rod: rod type Shibai leaf.
Terminal specifications: with wire, under the lead.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment D4NH-2DAS INSTRUCTION sheet.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free OMRON D4NH-2DAS Manual. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator) OMRON D4NH-2DAS Manual.
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note OMRON D4NH-2DAS Manual. ): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion poinnt D4NH-2DAS .
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4NH-2DAS INSTRUCTION sheet.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety-door Hinge Switch
D4NH-2BBC
OMRON Safety-door Hinge Switch D4NH-2BBC
Actuator: Arm lever. Conduit size: 1-conduit
OMRON
Safety-door Hinge Switch
D4NH-2FBC
OMRON Safety-door Hinge Switch D4NH-2FBC
Actuator: Arm lever. Conduit size: 1-conduit
OMRON
Safety-door Hinge Switch
D4NH-4FBC
OMRON Safety-door Hinge Switch D4NH-4FBC
Actuator: Arm lever. Conduit size: 1-conduit
OMRON
Safety-door Hinge Switch
D4NH-8BBC
OMRON Safety-door Hinge Switch D4NH-8BBC
Actuator: Arm lever. Conduit size: 2-conduit