LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> touch screen A956GOT-SBD-B Connection System Manual Manual MITSUBISHI A956GOT-SBD-B User's Manual

touch screen A956GOT-SBD-B Connection System Manual Manual MITSUBISHI A956GOT-SBD-B User's Manual

Product model: A956GOT-SBD-B
Name: touch screen
Brand: MITSUBISHI
Sort: Connection System Manual User's Manual
File language: English
File size: 4.71MB
Cable length: 35 meters.
For QCPU and GOT (need A9GT-QCNB) connection.
For the connection between GOT and GOT. AnS, QnAS bus connection, the reader to write program 2 channel connection.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register A956GOT-SBD-B Manual.
And then combine the data and the program with CPU A956GOT-SBD-B
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on A956GOT-SBD-B Manual.
This phenomenon is called the I/O delay time effect. Output type: transistor output, drain type.
Output points: 32 points.
OFF leakage current: 0 A956GOT-SBD-B Manual. 25mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 1 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program MITSUBISHI A956GOT-SBD-B User's Manual MITSUBISHI A956GOT-SBD-B User's Manual.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Input points: 16 points.
Input voltage and current: 120V ~ 10mA AC100 MITSUBISHI A956GOT-SBD-B User's Manual.
Input response time: 35ms.
16 point /1 a public side.
Output points: 12 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public end, 3 point /1 a public end.
Independent contact.
36 point terminal station.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission devicce, brake signal and fan fault signal A956GOT-SBD-B Connection System Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A956GOT-SBD-B Manual.
Related products
MITSUBISHI
6 inch man machine interface
A956GOT-LBD-M3
MITSUBISHI 6 inch man machine interface A956GOT-LBD-M3
Series Name: A956GOT. Size: 6 inches. Resolut
MITSUBISHI
6 inch man machine interface
A956GOT-TBD-M3
MITSUBISHI 6 inch man machine interface A956GOT-TBD-M3
Series Name: A956GOT. Size: 6 inches. Resolut
MITSUBISHI
6 inch man machine interface
A956GOT-LBD
MITSUBISHI 6 inch man machine interface A956GOT-LBD
Series Name: A956GOT. Size: 6 inches. Resolut
MITSUBISHI
6 inch man machine interface
A956GOT-TBD
MITSUBISHI 6 inch man machine interface A956GOT-TBD
Series Name: A956GOT. Size: 6 inches. Resolut