LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> D4N-9125 PDF catalog OMRON Safety Limit Switch D4N-9125 datasheet PDF datasheet

D4N-9125 PDF catalog OMRON Safety Limit Switch D4N-9125 datasheet PDF datasheet

Product model: D4N-9125
Name: Safety Limit Switch
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 5.69MB
Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ OMRON Safety Limit Switch PDF datasheet.
Conduit size (See Note D4N-9125): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) OMRON Safety Limit Switch PDF datasheet.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors OMRON Safety Limit Switch PDF datasheet. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action) D4N-9125 PDF datasheet.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms D4N-9125 PDF datasheet.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4N-9125 PDF datasheet.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller plunger.
Conduit openings: M20.
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mecchanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4N-9125 PDF catalog.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) OMRON Safety Limit Switch PDF datasheet.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-1B2HR
OMRON Pull-reset Safety Limit Switch D4N-1B2HR
Actuator: Adjustale roller lever, form lock
OMRON
Pull-reset Safety Limit Switch
D4N-2C2GR
OMRON Pull-reset Safety Limit Switch D4N-2C2GR
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-8B22
OMRON Safety Limit Switch D4N-8B22
Actuator: Roller lever resin lever, resin ro
OMRON
Safety Limit Switch
D4N-1F72
OMRON Safety Limit Switch D4N-1F72
Actuator: One-way roller arm lever vertical