Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks OMRON G3F Series/G3FD Series PDF datasheet.
DIN Track mounting types and screw mounting types are available
G3F Series/G3FD Series
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Control terminal block: Terminal block with small slotted screws.
Type: Standard.
Capacity: 20 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No OMRON G3F Series/G3FD Series PDF datasheet.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control OMRON G3F Series/G3FD Series PDF datasheet.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified. Main contacts: 3PST-NO.
Auxiliary contact: SPST-NC.
OFF-delay time: 30 S.
The G9SA Series Offers a Complete.
Line-up of Compact Units.
Four kinds of 45-mm wide Units are available:
A 3-pole model, a 5-pole model, and models with 3 poles,
and 2 OFF-delay poles, as well as a Two-hand Controller.
Also available are 17.5-mm wide Expansion Units with 3,
poles and 3 OFF-delay poles.
Simple expansion connection.
OFF-delay models have 15-step OFF-delay settings.
Conforms to EN ISO13849-1 (PLe/Safety Category 4).
Both DIN track mounting and screw mounting are possible. Input capacity: 32 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 100 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 210 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,,
each connector G3F Series/G3FD Series PDF catalog.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
swwitch and with tool software G3F Series/G3FD Series PDF catalog.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.