Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element OMRON K8AB-VS Series PDF catalog.
Burnout Detector compatible with a,
wide-range of heater control methods
K8AB-VS Series
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance OMRON K8AB-VS Series PDF catalog.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA OMRON K8AB-VS Series PDF catalog.
Transistor: -; NPN open collector (OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed pulse.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse is 25kHz, increase or decrease of pulseCategory: ontology; power monitoring.
Application circuit: single phase 2 wire; single phase 3 wire; three-phase 3 wire.
Supply voltage: AC100 ~ 240V (50/60Hz).
Output function: open collector output; cumulative output pulse output; alarm output.
Communication specifications: RS-485.
Memory card function: have.
Simple monitoring of the use of electricity to support energy saving countermeasures.
On behalf of the use of the mechanical equipment, the measurement of the innitial voltage, current,
Cumulative quantity, invalid power, power factor, frequency K8AB-VS Series PDF datasheet.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network K8AB-VS Series PDF datasheet.
Wide 45mm miniaturization, simple set to the DIN guide.