Operation control mode: stored procedure repeated operation.
Built in IE CC-Link.
Input / output points: 4096 points.
Program capacity: 160K step.
Easy to collect and display the value of soft component.
With simple parameter setting, the value of the soft component can be collected as the record data,
Save to the SD memory card, or through the USB/ Ethernet for real-time monitoring RX40PC6H PDF datasheet
RX40PC6H
Using the data collected by the recording function to support the Unicode text format,
Can be easily recognized by LogViewer GX and spreadsheet software.
In addition, LogViewer GX can also be used to monitor the function of real time,
Easily confirm the time of small changes in the object''s soft components.
These features can be traced back to improve and set up a fault when the commissioning of a great help RX40PC6H PDF datasheet. Output points: 32 points.
Output form: Transistor (source) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.1A/ point.
Response time: 1ms.
Common way: 32 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 40 pin connector RX40PC6H PDF datasheet.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type.
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance. The input and output module installation number: 12.
Can install module: MELSEC-Q series module.
DIN guide rail mounting adapter type: Q6DIN1.
Size (H) * (44.1mm) * (W) * (D): * 439mm * 98mm.
Substrate module for mounting various modules of MELSEC-Q series.
Extended use of Q series expansion substrates in the following extensions. "Analog input channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:-.
Temperature coefficient: positive and negative 35ppm/.
Common
Conversion speed: 10ms.
Insulation between channels: isolation transformer insulation.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection mode: 40 pin connector.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
Analog input module for the external analog signal into the interface of the programmable controller.
Can choose the channel between the insulation, voltage input, current input, voltage / current mixed input, thermocouple input, temperature resistance (RTD) input for a variety of purposes, such as modules.
Filter high frequency interference.
Analog input module has been equipped with a first order lag filter.
The analog input signal with high frequency interference component can be obtained by using the first order lag filter.
Parameters can be set through the filter time constant, no program can be easy to use.
Execute event driven program through alaarm output
Strengthen the implementation of the interrupt function according to the alarm output flag, easy to carry out preventive maintenance RX40PC6H PDF catalog.
The measured value and the change rate of the analog input signal exceed the upper and lower limits of the set,
Regardless of the procedure of the scan time, can be executed interrupt handling, quickly respond to abnormal conditions RX40PC6H PDF catalog.