"Input points: 16 points.
Rated input voltage and frequency: DC24V.
Rated input current: TYP 7.0mA.
Response time: 0.1 ~ 70ms.
Common way: 16 point / public end.
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input and output module is the interface between the switch, sensor, actuator, and other control system of the ON/OFF signal processing.
Compared with the previous series, iQ-R MELSEC series of input and output modules have more features,
1 modules can be used for a variety of purposes, to help reduce the cost of deployment and maintenance costs.
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors.
The input and output number stamped on the top of the front display input and output module LED, can easily confirm the status of the ON/OFF.
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented.
The 64 point module can be 32 points as the unit, through the switch to switch to display the input and output number.
In addition, serial number tag in the front of the module, can be easily recognized. "
230.4kbps Max., RS-232 2 channel.
When using the serial communication module, it is only necessary to select from the communication protocol library of engineering software,
Can carry out data communication support MODBUS general agreement.
2 channels are supported 230.4kbps, communication can fully play the performance of the matching equipment MITSUBISHI RX40C7. Analog input channel number: 4CH
RX40C7
Available thermocouple: B, R, S, K, E, J, T, N, U, L, PL II, W5Re/W26Re.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range MITSUBISHI RX40C7.
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: none.
External wiring connection mode: 18 point screw terminal.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control MITSUBISHI RX40C7.
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater.
Reduce the incidence of non qualified products by inhibiting the effect of external interference,
Improve the efficiency of life and product quality by using external interference suppression function,
The temperature fluctuation caused by external disturbance can be rapidly attenuated,
To ensure that the product processing within the specified temperature range, reduce the incidence of substandard products MITSUBISHI Extended SRAM card MITSUBISHI Extended SRAM card.
This function is very effective for the product packaging machine and injection molding machine, the semiconductor manufacturing device of the wafer heating board and so on MITSUBISHI Extended SRAM card. 10Mbps Max., master / local station, support Ver.2 CC-Link.
CC-Link is a bus (RS-485) - type open field network which can control and information processing at the same time.
Can be in the CC-Link and high-speed transmission of ON//OFF information from the station equipment, such as bit data, analog information, such as digital data RX40C7.
Connect all kinds of field equipment through CC-Link.
Can connect all kinds of support CC-Link field equipment, according to vvarious control requirements to build the corresponding system MITSUBISHI RX40C7.
Use remote device network mode, up to 64 remote equipment such as analog devices, etc..