I/O classification: Output.
I/O points: 16.
Internal I/O circuit common: NPN (+ common).
Rated voltage: 12 VDC, 24 VDC.
Single Cable Connection to PLC Means.
Space is Saved and Less Control Panel.
Wiring is Required.
Compact size: 182 (W) 85 (D) 68 (H) mm,
(8-point Output Block width is 102 mm) G3FD-102S DC3-28 PDF datasheet.
Connects to the PC through the connecting cable,
(G79 Series) and connector, and requires only a,
snap-in operation
G3FD-102S DC3-28
Surge suppressor circuit built-in.
Immediate recognition of I/O signal status using,
LED operation indicators.
G3TA I/O Solid-state relay can be mounted instead,
of G7T.
Mounts easily on a DIN track.
Approved by UL, CSA (except for G7TC-OC16-1). Insulation method: Photovoltage coupler G3FD-102S DC3-28 PDF datasheet.
Operation Display: Yes(green).
Output(SSR): DC.
Zero cross Function: --.
Rated output Load: 3 A(at 5 to 24 VDC).
Rated input voltage (socket): 12 VDC.
Applicable model: G3RV-SR700/500-A DC12V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel G3FD-102S DC3-28 PDF datasheet.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Control terminal block: Screwless clamp terminal block.
Type: Standard.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current G3FD-102S DC3-28 PDF catalog.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G3FD-102S DC3-28 PDF catalog.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.