I/O SSRs That Mount to OMRON’s G7TC I/O Block.
Input and output modules are available in wide variety.
Snaps easily into P7TF I/O Terminals and can be used together,
with G7T I/O relays.
Operation of each SSR can be monitored easily through an LED indicator.
Models certified for UL and CSA added to the series ("-US" models) G3FD-X03S DC3-28 PDF datasheet. Terminal (Wire connection): Push-In Plus Terminal
G3FD-X03S DC3-28
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC, 200V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape G3FD-X03S DC3-28 PDF datasheet.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging G3FD-X03S DC3-28 PDF datasheet. Classification: LED indicator and diode with test button.
Coil ratings: DC 6, 12, 24, 48.
Contact form: SPDT.
Slim and Space-saving Power Plug-in Relay.
Reduces wiring work by 60% when combined with the,
P2RF-@-PU Push-In Plus Socket.
(according to actual OMRON measurements).
Lockable test button models available.
Built-in mechanical operation indicator.
Provided with nameplate.
AC type is equipped with a coil-disconnection self-diagnostic,
function (LED type).
High switching power (1-pole: 10 A). Type: output module.
Insulation: photo coupler.
Zero crossing function: No.
Action display lamp.
Output rated voltage: DC5 3A ~ 48V.
Input rated voltage: DC5 ~ 24V.
Logic circuit and load interface.
I/O solid state relay.
With the input module (AC, DC), the output module (AC, DC).
Product series, the color of each module to distinguish.
You can confirm the action of SSR by using the action display light.
Between input and output voltage 4000V. Input capacity: 32 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 100 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 210 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provideed for,
each connector G3FD-X03S DC3-28 PDF catalog.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
swwitch and with tool software G3FD-X03S DC3-28 PDF catalog.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.