Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC, 100V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel G3J-211BL AC100-240 PDF datasheet.
Realized opening and closing ability with one pole 6 A slim shape
G3J-211BL AC100-240
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs G3J-211BL AC100-240 PDF datasheet.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Type: Standard.
Latching lever (Test switch): NO.
Rated input voltage: DC, 11.
Applicable model: G2RV-SR700/500 DC12V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel G3J-211BL AC100-240 PDF datasheet.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided ffor,
each connector G3J-211BL AC100-240 PDF catalog.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
swwitch and with tool software G3J-211BL AC100-240 PDF catalog.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.