LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-XAD-L2AT11 AC100-240 PDF catalog K3HB-XAD-L2AT11 AC100-240 datasheet PDF datasheet

OMRON K3HB-XAD-L2AT11 AC100-240 PDF catalog K3HB-XAD-L2AT11 AC100-240 datasheet PDF datasheet

Product model: K3HB-XAD-L2AT11 AC100-240
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.90MB
Applicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC.
Power supply voltage (shared): 100 to 240 VAC.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model K3HB-XAD-L2AT11 AC100-240 PDF datasheet K3HB-XAD-L2AT11 AC100-240 )
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function K3HB-XAD-L2AT11 AC100-240 PDF datasheet.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power K3HB-XAD-L2AT11 AC100-240 PDF datasheet.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideaal indicator for judging whether an automatic device and a screening device are qualified K3HB-XAD-L2AT11 AC100-240 PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K3HB-XAD-L2AT11 AC100-240 PDF catalog.
External event input can be applied to a variety of measurement and identification situations.
Can enter DC0.001m
Related products
OMRON
Time interval table
K3HB-PNB-FLK1AT11 AC100-240
OMRON Time interval table K3HB-PNB-FLK1AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Time interval table
K3HB-PNB-L2AT11 AC100-240
OMRON Time interval table K3HB-PNB-L2AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Rotating pulse meter
K3HB-RNB-FLK3AT11 AC100-240
OMRON Rotating pulse meter K3HB-RNB-FLK3AT11 AC100-240
Input type: NPN/ voltage pulse input type. E