Name: Safety Controller.
Number of I/O: Safety inputs, 20; Test outputs, 6;
Safety outputs, Solid-state outputs: 8; Standard outputs, --.
Unit version: Ver.2.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application G3RV-SR500-A AC100 PDF datasheet.
Four types of Expansion I/O Units for hard-wired diagnosis or standard signals
G3RV-SR500-A AC100
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, verification, standardization and reusage of,
safety control by unique programming software.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified G3RV-SR500-A AC100 PDF datasheet. Item: Basic model.
DPDT: Rated voltage, 12 VAC, 24 VAC, 50 VAC, 100/(110) VAC,
200/(220) VAC, 12 VDC, 24 VDC, 100 VDC, 200 VDC.
Unique Ratchet Mechanism Assures Positive.
Alternate Transfer/Switching Operation.
Each contact in the double-pole contact mechanism performs.
alternate make-brake operation at each pulse input and is thus G3RV-SR500-A AC100 PDF datasheet.
ideal for alternate operation or transfer/switching operation of a motor.
Positive operation is assured due to the unique ratchet mecha nism.
Satisfies dielectric strength of 2,000 VAC.
Low power consumption.
(AC: approx. 6.4 VA; DC: approx. 3.9 W). Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 15 A, 100 to 240 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 50 A at 200 to 480 VAC.
Rated input voltage: 12 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mountiing possible via screws or via DIN track G3RV-SR500-A AC100 PDF catalog.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply witth VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load G3RV-SR500-A AC100 PDF catalog.
Certified by UL, CSA, and VDE (reinforced insulation).