Name: Safety Controller.
Number of I/O: Safety inputs, 10; Test outputs, 6;
Safety outputs, Solid-state outputs: 16; Standard outputs, --.
Unit version: Ver.2.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application G3TA Series PDF datasheet.
Four types of Expansion I/O Units for hard-wired diagnosis or standard signals
G3TA Series
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, verification, standardization and reusage of,
safety control by unique programming software G3TA Series PDF datasheet.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified. Structure: plastic sealed.
Contact structure: 1C.
Coil rated voltage: DC3V.
Small, high sensitivity 1 pole signal relay.
Small size 12.5 (L) * 7.5 (W) * 10 (H) mm.
Wide range of contact switch area 1mA ~ 1A.
High sensitivity coil 150mW.
Plastic sealed type, excellent environmental performance.
Coil contact between the Part68 FCC standard G3TA Series PDF datasheet. (1500V, 10 * 160 s)Name: System Units; I/O Power Feed Unit.
Specifications: Use when the total current,
consumption of the I/O Power Supply exceeds 4 A,
or to make the I/O Power Supply a separate system.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Input terminals: M3 terminals.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heeaters G3TA Series PDF catalog.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) G3TA Series PDF catalog.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.