Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24.
Temperature indicator and measurement of various processes K3HB-PPB-CPAC11 AC/DC24V PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display
K3HB-PPB-CPAC11 AC/DC24V
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
By 2 points can be easily set the temperatureIdeal for Monitoring 3-phase Power Supplies,
for Industrial Facilities and Equipment K3HB-PPB-CPAC11 AC/DC24V PDF catalog.
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, phase sequence, and phase loss,
in three-phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Time specification: Instantaneous type K3HB-PPB-CPAC11 AC/DC24V PDF catalog.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) OMRON Time interval table PDF catalog.
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase OMRON Time interval table PDF catalog.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON Time interval table PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-232C; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply vvoltage: AC100 ~ 240V K3HB-PPB-CPAC11 AC/DC24V PDF datasheet.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurementt of wide range of pulse interval time K3HB-PPB-CPAC11 AC/DC24V PDF catalog.
Measuring, calculating and displaying the pulse interval between 2 points.
Range of pulse interval measurement