Setting range: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment K3HB-VLC-L1BT11 AC100-240 PDF catalog.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltages.
Manual resetting and automatically resetting supported by one Relay
K3HB-VLC-L1BT11 AC100-240
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator K3HB-VLC-L1BT11 AC100-240 PDF catalog.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: BCD+ transistor; - NPN open collector (5 bit outtput +HH, H, PASS, L, LL) K3HB-VLC-L1BT11 AC100-240 PDF catalog mV instrument PDF catalog.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors.
Equipped with the sub pressure gauge for monitoring the operation trend OMRON Load sensor.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) onlyPower supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control OMRON Load sensor.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods OMRON Load sensor.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase contrrol, and cyclic control K3HB-VLC-L1BT11 AC100-240 PDF datasheet.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads mV instrument PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).