Type of input: AC current input.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-VLC-L2BT11 AC100-240 PDF catalog.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K3HB-VLC-L2BT11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations K3HB-VLC-L2BT11 AC100-240 PDF catalog.
DeviceNet type systemInput type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Communication: RS-485; NPN open collector (OUT5, OUT4, OUT3, OUT2, OUT1) K3HB-VLC-L2BT11 AC100-240 PDF catalog mV instrument PDF catalog.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed pulse.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display OMRON Load sensor.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
The cumulative pulse input is 50kHz, the phase difference pulse is 25kHz, and the phase difference pulse is increased Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control OMRON Load sensor.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods OMRON Load sensor.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase contrrol, and cyclic control K3HB-VLC-L2BT11 AC100-240 PDF datasheet.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads mV instrument PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).