Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-XAA-FLK1AT11 AC100-240 PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K3HB-XAA-FLK1AT11 AC100-240
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XAA-FLK1AT11 AC100-240 PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input K3HB-XAA-FLK1AT11 AC100-240 PDF datasheet.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 320Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, orr cycle of the digital time interval table K3HB-XAA-FLK1AT11 AC100-240 PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and dispplaying the pulse interval between 2 points K3HB-XAA-FLK1AT11 AC100-240 PDF catalog.
Pulse interval measurement range, the maximum measurable range from 10ms to 3200s.
6 measurement methods,