Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
Supply voltage: 24, 100 to 120, 200 to 230 VAC; 12, 24, 48, 100 to 110, 125 VDC.
Time-limit contact: DPDT.
Short-time range model (0.1 s to 10 min).
Miniature Timer with Multiple Time Ranges,
and Multiple Operating Modes.
UL listed when used with a Push-In Plus Terminal Block Socket.
Conforms to CSA, CE Marking, LR, and CCC OMRON K3HB-XVA-L2AT11 AC100-240.
Black design with power supply terminals on top and contact output,
terminals on bottom
K3HB-XVA-L2AT11 AC100-240
Standard multiple operating modes and multiple time ranges.
Pin configuration compatible with MY Power Relay.
Minimizes stock. Supply voltage: 24 VAC; 12, 24 VDC.
Time-limit contact: SPDT.
Short-time range model (0.1 s to 10 min).
Compact, Multi-function Timers,
for G2R Relay Socket OMRON K3HB-XVA-L2AT11 AC100-240.
The Push-In Plus Terminal Block Socket-compatible H3RN-@-B.
Timers in a black design join the Compact, Multi-function H3RN Timers.
Standard multiple time ranges and multiple operating modes.
UL listed.
Conforms to CSA and CE Marking. Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or PNP input.
Output type: Judgement output, 3 transistor outputs (PNP open collector);
Data transmission output, None OMRON K3HB-XVA-L2AT11 AC100-240.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red OMRON Voltage and current panel meter.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66) OMRON Voltage and current panel meter. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Moode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 OMRON Voltage and current panel meter K3HB-XVA-L2AT11 AC100-240.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input) OMRON K3HB-XVA-L2AT11 AC100-240.
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.