Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load) K3HB-XAD-CPAC21 AC/DC24 PDF datasheet.
Output relay can be switched between normally open and normally closed
K3HB-XAD-CPAC21 AC/DC24
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Rated input voltage: 3-phase 3-wire mode, 380, 400, 415, or 480 VAC K3HB-XAD-CPAC21 AC/DC24 PDF datasheet.
Ideal for Monitoring 3-phase Power Supplies,
for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, phase sequence, and phase loss,
in three-phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator K3HB-XAD-CPAC21 AC/DC24 PDF datasheet. Category: ontology; power monitoring.
Application circuit: single phase 2 wire; single phase 3 wire; three-phase 3 wire.
Supply voltage: AC100 ~ 240V (50/60Hz).
Output function: open collector output; cumulative output pulse output; alarm output.
Communication specifications: RS-485.
Memory card function: No.
Simple monitoring of the use of electricity to support energy saving countermeasures.
On behalf of the use of the mechanical equipment, the measurement of the initial voltage, current,
Cumulative quantity, invalid power, power factor, frequency.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network.
Wide 45mm miniaturization, simple set to the DIN guide. Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 00 to 5 A) K3HB-XAD-CPAC21 AC/DC24 PDF catalog.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can bbe switched between normally open and normally closed K3HB-XAD-CPAC21 AC/DC24 PDF catalog.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.