Product name: N@@S1- type CPU Units with 60 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 36; Outputs, 24;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.21A; 24 V,0.13A.
Standards: CE CS1W-BC032 PDF datasheet .
The CP1E Programmable Controller: Economical, Easy to use, and Efficient
CS1W-BC032
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT201.
Master station unit remote I/O CS1W-BC032 PDF datasheet . Unit type: CJ1 Basic I/O Units.
Product name: Relay Contact Output Units.
Specifications: Output type , --;
I/O points, 8 inputs;
Maximum switching capacity, 250VAC/24VDC, 2A;
Commons, Independent contacts;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.09A; 24V, 0.048A max.
Standards: UC1, N, L, CE CS1W-BC032 PDF datasheet .
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices OMRON CS1W-BC032 PDF catalog.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs) OMRON CS1W-BC032 PDF catalog.
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Universal
inputs: Pt100 (3-wire), JPt100 (3-wire),
Pt1000 (3-wire), Pt100 (4-wire), K, J,
T, E, L, U, N, R, S, B, WRe5-26, PL II,
4 to 20 mA, 0 to 20 mA, 1 to 5V, 0 to 1 OMRON CS1W-BC032 PDF catalog. 25V,
0 to 5V, 0 to 10V, ±100 mV selectable range,
-1.25 to 1.25 V, -5 to 5 V, -10 to 10V,
±10V selectable range, potentiometer.
Conversion speed (resolution): Resolution
(conversion speed): 1/256,000 (conversion cycle:
60 ms/ 4 inputs) 1/64,000 (conversion cycle:
10 ms/4 inputs) 1/16,000 (conversion cycle:
5 ms/4 inputs).
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Curreent consumption: 5V, 0 CS1W-BC032 datasheet. 30A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CS1W-BC032 PDF datasheet .
All inputs are isolated.