Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 2 square mm.
Weight: 0.7kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Frequency converter input power: 3 phase AC400V OMRON Time lnterval Meter INSTRUCTION SHEET.
Weight: 1.6KG.
Standard applicable line diameter: 2 square mm or more
3G3MX2-A2150
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Specification: small.
Impact resistance: 120W.
Resistance to impact resistance: 35.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down OMRON Time lnterval Meter INSTRUCTION SHEET.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed. Specification: three phase 400V.
Power: 220KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380 OMRON Time lnterval Meter INSTRUCTION SHEET.
Weight: about 280kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive 3G3MX2-A2150 INSTRUCTION SHEET.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV 3G3MX2-A2150 INSTRUCTION SHEET.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. Level: 3 phase 200V level 3G3MX2-A2150 INSTRUCTION SHEET.
Connecting resistance: 17 or more.
Internal resistance value: 120W, 180W.
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time.
Alarm output terminal of regenerative braking unit.
The temperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter. Specification: medium capacity type.
IImpact resistance: 600W 3G3MX2-A2150 Manual.
Resistance to impact resistance: 35.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resisttor OMRON Time lnterval Meter INSTRUCTION SHEET.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed.