Model : CV500-CPU01-V1.
SFC / Ladder 512 (with RAM30K words, the top internal link).Specifications: Without clock (see below).Name: Analog I/O Slave Units,
(Numerical indicator type)
e-CON Connector Type.
Specifications: Analog outputs; 2 outputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON Programmable Terminals HOST CONNECTION MANUAL.
Branching is easily made with CompoNet
CJ1H-CPU64H-R
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON Programmable Terminals HOST CONNECTION MANUAL. Model: C200H-OC226N.
No. of points: 16 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Unit type: CJ1 CPU Bus Unit.
Product Name: Controller Link Unit.
Specifications:Communications cable,
Wired shielded wisted-pair cable ;
Communications type,
Data links and message service;
Duplex support, No;
Max OMRON Programmable Terminals HOST CONNECTION MANUAL. Units mountable per CPU Unit, 8;
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.35A; 24V,--.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words CJ1H-CPU64H-R HOST CONNECTION MANUAL.
The Controller Link is an FA,
network that can send and receive,
large amounts of data easily,
and at high speed.
The Controller Link supports data,
links that enable sharing,
data between PLCs and computers,
and a message service that enables,
sending and receiving data whenever required CJ1H-CPU64H-R HOST CONNECTION MANUAL.
Systems can be flexibly built by using Repeater,
Units to enable T-branches, long-distance wiring,
and converting part of the network to optical cable CJ1H-CPU64H-R HOST CONNECTION MANUAL. Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Platinum ,
resistance thermometer input(JPt100, Pt100);
Control outputs: Open collector NPN outpputs (pulses) CJ1H-CPU64H-R Manual.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output OMRON Programmable Terminals HOST CONNECTION MANUAL.