Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/4 inputs.
Externa connection: Removable erminal block OMRON DeviceNet MULTIPLE I/O TERMINAL OPERATION MANUAL.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0
CJ1W-MD23225A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON DeviceNet MULTIPLE I/O TERMINAL OPERATION MANUAL.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems OMRON DeviceNet MULTIPLE I/O TERMINAL OPERATION MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CJ1W-MD232 OPERATION MANUAL.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools CJ1W-MD232 OPERATION MANUAL. Product name: CJ1M CPU Units; built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
640 points/20 Units(1 Expansion Racks max.) ; Program capacity,
20K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0 CJ1W-MD232 OPERATION MANUAL. 1 μs;
Built-in I/O , 10 inputs and6 outputs,
2 counter inputs, 2 pulse outputs.
Current consumption: 5v, 0.64A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. C500-IA I/O Unit AC Input 16 pts C500-IA222(3G2A5-IA222).
AC200-240V 10mA.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector,
PNP outputss (pulses) CJ1W-MD232 Manual.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output OMRON DeviceNet MULTIPLE I/O TERMINAL OPERATION MANUAL.