Name: e-CON Connectors.
Specifications: Inputs; 32 inputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CJ1W-TC004 PROGRAMMING MANUAL.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CJ1W-TC004
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 16 outputs;
Maximum switching capacity, 24VDC,
0 CJ1W-TC004 PROGRAMMING MANUAL. 5A Short-circuit protection;
Commons, 16 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.10A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices CJ1W-TC004 PROGRAMMING MANUAL.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system OMRON CJ1W-TC004 Manual.
throughput. Output method: Analog resolution: 1/6000.
Analog Outputs: 4.Programmed using the Fuzzy Support Software. Up to 8 inputs and 4 outputs.NO OMRON CJ1W-TC004 Manual. OF I/O SLOTS: 6 SLOTSConnects Power Supply Adapter and SYSMAC NET Link Unit.
Included with C200H-APS02.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Pulse Input Unit.
Input points : 4 pulse inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1 OMRON CJ1W-TC004 Manual.
Current consumption: 5V, 0.20A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space comparedd,
with previous systems CJ1W-TC004 .
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-TC004 PROGRAMMING MANUAL.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.