Name: CS1D CPU Backplane.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System only;
Number of Power Supply Units, 2 Units max.
(for duplex operation);
Number of I/O Units, 5 Units max.
Current consumption: 5V system, 0.55A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables OMRON CP1E-E10DT1-D Manual
CP1E-E10DT1-D Name: MIL Connectors.
Specifications: Outputs; 32 outputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON CP1E-E10DT1-D Manual.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Description : Connects peripheral port to RS232C computer port (Use with CS1W-CN114).I/O points: 256 pts.
Program capacity(words): 7 OMRON CP1E-E10DT1-D Manual. 2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Analog setting: YES.Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. vName: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduceed CP1E-E10DT1-D REFERENCE MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CP1E-E10DT1-D REFERENCE MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.