I/O capacity: 2.048 pts (6, 144 max. with remote I/O).
Execution time: Basic: 0.125 µs min.Special: 0.5 µs min.
Model : CVM1-PRS21-EV2.
For ladder.Model: CPM2A-20CDR-A. Power supply: AC power supply.
Output type: Relay.
Inputs points: 12 points.
Outputs points: 8 points.I/O capacity: 512 pts (2, 048 max CP1L-EM40DT1-D Manual. with remote I/O).
Execution time: Basic: 0.15 µs min
CP1L-EM40DT1-DSpecial: 0.6 µs min.
Unit type: CJ1 Basic I/O Units.
Product name: Interrupt Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24 VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block CP1L-EM40DT1-D Manual.
No. of words allocated: 1 word.
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE.
High-speed Starting of I/O InterruptTasks.
Use Up to Two Units for a Total of Up,
to 32 Interrupt Inputs.
Receive inputs to start I/O interrupt tasks.
When the Interrupt Input Unit receives an input,
the CPU Unit will interrupt execution of the,
cyclic tasks in the normal CP1L-EM40DT1-D Manual.
program and execute an I/O interrupt task. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON CP1L-EM40DT1-D REFERENCE MANUAL.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON CP1L-EM40DT1-D REFERENCE MANUAL.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON CP1L-EM40DT1-D REFERENCE MANUAL. I/O Control UnitProvided with SYSMAC LINK Unit.A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems. Unit type: CS1 Basic I/O Units.
Product name: Interrupt Input Unit.
Specifications: I/O points,
16 inputs; Input voltage, 24 VDC;
Input current, 7 mA; Input pulse width,
ON time, 0.1 ms max, OFF time,
0.5 ms max; External connection,
Remov able terminal block.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No CP1L-EM40DT1-D .
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 1 word.
Current consumption: 5V system, 0.110A;
26 V system, -- CP1L-EM40DT1-D Manual.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control.