UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No. of I/O points: 880 points.
Max. no.of connecting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10 OMRON CPM2A-40CDR-A OPERATION MANUAL.
RS-232C: NO.Expands G730 input capacity of G730 remote master;
adds 32 or 16 inputs,
DIP switch selected
CPM2A-40CDR-AUnit type: CJ1 Basic I/O Units.
Product name: AC Input Units.
Specifications: I/O points, 16 inputs;
Input voltage and current: 100 to 120 VAC, 7 mA(100 V, 50 Hz);
Commons, 16 points, 1 common; External connection,
Removable Terminal Block; No. of words allocated, 1 word OMRON CPM2A-40CDR-A OPERATION MANUAL.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput OMRON CPM2A-40CDR-A OPERATION MANUAL.
UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Model: C200HW-ME16K.
Capacity: 16K words.Model: C200H-OC223.
No. of points: 5 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Name: Screw Terminal Block with SSR Outputs.
Specifications: Outputs;
16 outputs; SSR.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: e-CON Connectors.
Specifications: Inputs; 8 inputs ; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost cann be reduced CPM2A-40CDR-A Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CPM2A-40CDR-A Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.