Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 15 A, 100 to 240 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks GRT1-CT1-1 OPERATION MANUAL.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work
GRT1-CT1-1
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track GRT1-CT1-1 OPERATION MANUAL.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Contact form: 4PDT.
Classification: Standard model.
Plug-in terminals.
Fully Sealed Version of G2A that Displays Its.
Power in Adverse Environments.
Exhibits stable performance in an adverse atmosphere of,
harmful gas, moisture, or powdery dust due to its hermetically,
sealed construction GRT1-CT1-1 OPERATION MANUAL.
All the mechanical components of the Relay have been,
annealed to prevent gas generation inside the Relay.
Economical as compared with a hermetically sealed relay in a,
metallic enclosure. Name: Slice I/O Units; Counter Units OMRON GRT1-CT1-1 Manual.
Specifications: Counter inputs: 1,
External outputs: 1 PNP.
Standards: CE, UC, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON GRT1-CT1-1 Manual.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON GRT1-CT1-1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: AC 230V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screew loosening means maintenance-free application,
realizing high reliability GRT1-CT1-1 .
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs GRT1-CT1-1 OPERATION MANUAL.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.