Terminals: Push-In Plus terminal blocks.
Type: Output *2.
Points: 16.
Internal I/O circuit common: PNP (- common).
Rated voltage: 24 VDC.
I/O Relay Terminals with 16 Points and,
Push-In Plus terminal blocks to,
Downsize Control Panels and Save Labor.
I/O Relay Terminals with 16 points to mount G2RV Slim I/O Relays OMRON GT1-OD16DS PROGRAMMING MANUAL.
Push-In Plus terminal blocks are used to save wiring work in,
comparison with traditional screw terminals
GT1-OD16DS (Wiring time is,
reduced by 60%* in comparison with traditional screw terminals.).
Work is reduced ever further with one-step cable connection to the PLC.
Diode provided for coil surge absorption.
Operation indicators for immediate recognition of I/O signal status OMRON GT1-OD16DS PROGRAMMING MANUAL.
Accepts G3RV Slim I/O SSRs.
DIN Track or screw mounting. Easy-to-use, Space-saving Terminal Relay with Four-point Output.
Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D).
Each terminal circuit (with coil or contact) is independent from one another.
Short Bar ensures easy connection of common and adjacent terminals.
Provided with a terminal cover that prevents electric-shock ac cidents OMRON GT1-OD16DS PROGRAMMING MANUAL.
Relay and MOS FET relay models are available.
LED operation indicator.
Built-in diode absorbs coil surge.
Mounts either on DIN track or screws.
Tool for easy mounting or removal of Relays provided.
UL, CSA, and VDE certification for standard models (VDE: G6D-F4B only). Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 40 A at 24 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation). Type: Standard.
Sealing: Flux-tight.
Poles: 4 poles.
Contact configuration: 3PST-NO, SPST-NC.
Rated voltage: 12, 18, 21, 24, 48, 110 VDC.
Compact, Slim Relays Conforming to,
EN Standards.
Relays with forcibly guided contacts,
(EN50205 Class A, certified byy VDE) GT1-OD16DS Manual.
Supports the CE marking of machinery (Machinery Directive).
Helps avoid hazardous machine status when used as part of,
an interlocking circuit.
Four-pole and six-pole Relays are available.
The Relay’s terminal arrangemment simplifies PWB pattern design GT1-OD16DS Manual.
Reinforced insulation between inputs and outputs.
Reinforced insulation between some poles of different polarity.