LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> K8AC-H22CC-FLK Manual OMRON Digital Temperature Controllers K8AC-H22CC-FLK Communications Manual

K8AC-H22CC-FLK Manual OMRON Digital Temperature Controllers K8AC-H22CC-FLK Communications Manual

Product model: K8AC-H22CC-FLK
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 7.32MB
Open circuit mode: current circuit breaker.
Appearance: ADR shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 10VA below (except for reactor part).
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1A; closed circuit 110V 15A DC 1000 (L/R=0ms),
Open 110V 1A DC 1000 (L/R=25ms) OMRON Digital Temperature Controllers Communications Manual K8AC-H22CC-FLK
The relay control output circuit breaker switch: power capacity, switching capacity, AC110V/10A C110V/10A; (COS =1).
Quality: about 1kg.
External: Mount Searl N1.5.
High voltage grounding relay type K2GA thin,
Miniaturization, and digital type precision mounting.
Strong anti interference ability,
Stable operation in the arc grounding fault OMRON Digital Temperature Controllers Communications Manual.
Can carry out fine current adjustment, easy to coordinate.
Set alarm terminal.
The adjusting part of the action current is a rotary switch mode, which is convenient for adjustment. Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linear: current; NPN open collector (HH, H, PASS, L, LL) OMRON Digital Temperature Controllers Communications Manual.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K8AC-H22CC-FLK Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time K8AC-H22CC-FLK Communications Manual.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable from 10mType: Medium-sensitivity models.
Sensed current: 200 mA/500 mA(switchable).
Type: Delayed models.
Operating time: 0.3/0.8 s (switchable) K8AC-H22CC-FLK Communications Manual.
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher rreliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads K8AC-H22CC-FLK Manual.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutuually compatible OMRON Digital Temperature Controllers Communications Manual.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease.
Related products
OMRON
Digital Heater Element Burnout Detector
K8AC-H22CN-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H22CN-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H21CN-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H21CN-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H12CC-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H12CC-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H22PN-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H22PN-FLK
Power supply voltage: 100 to 240 VAC. Heater