Model: C500-AE001(3G2A5-AE001).
Output line driver converts the input open-collector output incremental encoder form, taking the position control unit.C500-OA I/O Unit Triac Output 16 pts C500-OA121(3G2A5-OA121).
AC132V 1A.Required for Analog Input and Output Units: For two Analog Units.C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT002-PV1 CP1L-M60DR-A Manual.
APF/PCF.With two optical connectorsModel: C500-BC052(3G2A5-BC052)
CP1L-M60DR-A
5 slots(5 linkable slots).
UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i CP1L-M60DR-A Manual. e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Number of outputs: 16 pts.
Max. switch-ing capacity: 50 mA at 4.5 V DC to 300 mA at 26.4 V.
External connector: Terminal block.
Weight: 210 g max.C500-IM I/O Unit INPUT MODULE 32POINT 24VAC/DC C500-IM212(3G2A5-IM212).
AC/DC12-24V 10mA。Provided with SYSMAC LINK Unit.Model : CV500-CN228.
BASIC for connecting the unit ← → FIT10 (2m) CP1L-M60DR-A Manual. CQM1-B7A Special I/O Unit 16 POINT IN /16 POINT OUT CQM1B7A01.CPU Unit: CP1L-EM CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Relay output;
Inputs, 18; Output, 12 OMRON Programmable Terminals Manual.
Standards: CE OMRON Programmable Terminals Manual.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams OMRON Programmable Terminals Manual. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CP1L-M60DR-A HOST CONNECTION MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1L-M60DR-A Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.