Model: C200H-TS001.
Temperature sensor: Thermocou-ples: K(CA), J(IC)(selectable).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).Communications protocol: Dedicated CompoBus/S protoco.
Code: Manchester code.Model : CVM1D-BI101.
10-slot.Product name: N@@-type CPU Units with 30 I/O Points CPM1A-40CDT-A-V1 .
Specifications: Power Supply, 100 to 240 VAC; Inputs, 8; Outputs, 6;
Output type: Transistor (sinking)
CPM1A-40CDT-A-V1
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.22A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality CPM1A-40CDT-A-V1 .
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. C500-RM SYSMAC BUS Remote I/O Master Wired C500-RM201.
Master station unit remote I/O.C500-OD I/O Unit Transistor Output 32 pts C500-OD412(3G2A5-OD412).
DC12~48V 0.3A.CV500-HD SYSMAC BUS PC Unit Hard Disk Drive For 100 VAC CV500-HDD01 CPM1A-40CDT-A-V1 . Model: C200H-IA121.
No. of inputs: 8 pts.
Input voltage: 100 to 120 VAC, +10%/–15%.
Input current: 10mA, 100VAC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 8 pts.
Internal currentcon-sump-tion: Connects to the I/O module located on the extreme right.Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; Outputs, 12;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.27A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Pulse Input Unit.
Input points : 4 pulse inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.20A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
wwith previous systems CPM1A-40CDT-A-V1 OPERATION MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CPM1A-40CDT-A-V1 OPERATION MANUAL.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.