Name: Compact Connectors.
Specifications: Inputs/Outputs; 2 input/2 output; NPN.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices CPM2A-60CDT1-D .
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price
CPM2A-60CDT1-D
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. Name: Compact Connectors.
Specifications: Inputs; 4 inputs; NPN.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery CPM2A-60CDT1-D .
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price.
Connectable with flat cables, too for easy wiring CPM2A-60CDT1-D .
Cables are selectable depending on applications. Product name: CJ2M CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2, 560 points/40 Units(3 ExpansionRacks max. );Programcapacity,
30K steps;Data memorycapacity, 160K words,
(DM: 32K words, EM: 32K words ×4 banks);
LD nstruction execution time, 0. 04 μs;
EtherNet/IP function: --;
Option board slot: --.
Current consumption (A): 5V, 0. 7(See note. );24V, --.
Standards: UC1, N, L, CE.
CJ2M for basic machine automation.
The CJ2M Series is ideal for packaging and general.
machine automation needs. Connectivity is assured.
thanks to the built-in USB port and the choice of.
Ethernet and RS-232C/422/485 interfaces on the CPU. Specification: 16 input points.C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT001-PV1.
APF/PCF, With the optical connector 1.Name: e-CON Connectors.
Specifications: Outputs; 8 outputs ; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-leevel I/O distribution reduces,
wiring in the system CPM2A-60CDT1-D Simple Operation Handbook.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CPM2A-60CDT1-D Simple Operation Handbook.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.