Unit classification: CJ1 Special I/O Units.
Product name: ProcessInput Units,
(Isolated-type Thermocouple Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Thermocouple: R, S, K, J, T, L, B.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs CPM2C-S100C Manual.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±1°C,
whichever is larger) ±1 digit max
CPM2C-S100C
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V) CPM2C-S100C Manual.
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Model: CPM2C-8EDM. Units with inputs only.
1 MIL connector.
Inputs: 8 inputs.
Outputs: ---.
Input type: 24 VDC.
Output type: --.Unit type: CS1 CPU Bus Unit.
Product name:FL-net Unit.
Specifications: Communications interface,
100BASE-TX; Communications functions,
With FL-net Ver CPM2C-S100C Manual. 2.0 specifications,
(OPCN-2) Data links and message service;
Max. Units mountable per CPU Unit,4.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.38A; 26V, -- OMRON Programmable Terminals Manual.
Standards: UC1, CE.
Connect to Multivendor Controller Networks.
This Unit allows you to connect to FL-net,
an open network based on Ethernet OMRON Programmable Terminals Manual.
Multivendor FL-net networks can be built to,
combine CS series PLCs with CNC machines,
robots, and PLCs from other manufacturers. Model: C200H-PS221.
Supply voltage: 120/240VAC.Cover for 10-pin terminal block.
Terminal cover for 8-point or 5-point I/O Units.Description : Connects peripheral port to D-sub 9pin connector OMRON Programmable Terminals Manual.
Must be used with CS1W-CN114 (3.3m).Name: Screw Terminal Block with Relay Outputs.
Specifications: Outputs;
16 outputs; Contacts.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost ccan be reduced CPM2C-S100C OPERATION MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CPM2C-S100C Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.