Model: CPM2C-8EDC. Units with inputs only.
1 Fujitsu connectors.
Inputs: 8 inputs.
Outputs: ---.
Input type: 24 VDC.
Output type: --.Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 8; Outputs, 6;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words CPM2C-S110C-DRT OPERATION MANUAL.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0
CPM2C-S110C-DRT17A; 24 V,0.07A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CPM2C-S110C-DRT OPERATION MANUAL. C500-OD I/O Unit Transistor Output 32 pts C500-OD414(3G2A5-OD414).
DC12~48V 0.3A.2 platinum resistance thermometer inputsName: Two-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; NPN.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet CPM2C-S110C-DRT OPERATION MANUAL.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CS1 Special I/O Units.
Connected ID System: V680 Series;
1 Head.
External power supply : --.
No. of unit numbers used: 1 unit number.
Current consumption: 5V, 0.26A; 26V, 0.13A;
External, --.
Communication Unit Dedicated for RFID,
V680 Allowing Direct Connection to,
OMRON PLC CJ/CS/NJ-series.
Communication unit for connecting RFID,
V680-series, which can be used around,
the world, directly to PLC.
Allows batch transfer of data up to 32 kbytes. C500-AD Special I/O Unit Analog Input C500-AD101.
Input: 8 pts.
Specification: 0~+10V、4~20mA.Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Universal
inputs: Pt100 (3-wire), JPt100 (3-wire),
Pt1000 (3-wire), Pt100 (4-wire), K, J,
T, E, L, U, N, R, S, B, WRe5-26, PL II,
4 to 20 mA, 0 to 20 mA, 1 to 5V, 0 to 1.25V,
0 to 5V, 0 to 10V, ±100 mV selectable range,
-1.25 to 1.25 V, -5 to 5 V, -10 to 10V,
±10V selectable range, potentiometer.
Conversion speed (resolution): Resolution
(conversion speed): 1/256,000 (conversion cycle:
60 ms/ 4 inputs) 1/64,000 (conversion cycle:
10 ms/4 inputs) 1/16,000 (conversion cycle:
5 ms/4 inputs).
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Cuurrent consumption: 5V, 0 CPM2C-S110C-DRT Manual. 30A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CPM2C-S110C-DRT Manual.
All inputs are isolated.