Model: C200H-ID216.
No. of points: 64 pts.
Specifications: 24VDC.
Weight: 180g max.Name: MIL Connectors.
Specifications: Inputs;
16 inputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CS1H-CPU63H .
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CS1H-CPU63H
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. CPU Unit: CP1L-L CPU Units with 10 Point CS1H-CPU63H .
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 6; Output, 4.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port CS1H-CPU63H .
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector PNP outputs (pulses).
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Connection type: Screw - Screw.
Description: Controller link repeater unit (wire to wire).Unit type: CJ1 Basic I/O Units.
Product name: Quick-response Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max CS1H-CPU63H Installation Guide. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CEE CS1H-CPU63H Installation Guide.
Capture Input Signals Shorter,
Than the Cycle Time.
This Input Unit can read pulse inputs that,
are shorter than the cycle time of the CPU Unit.