Required for Analog Input and Output Units: For one Analog Unit.CV500-SL CPU Bus Unit for Com SYSMAC LINK Unit SYSMAC LINK Unit (coaxial) CV500-SLK21.CVM1-CL Special I/O Unit Communication Link Unit CVM1-CLK21.NO. OF I/O SLOTS: 8 SLOTSOutput method: Transistor sinking.
Inputs: ---.
Outputs: 32.Name: CS1D CPU Unit for Single CPU Systems CS1W-AD041-V1 USER'S MANUAL.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 60 Ksteps;
Data Memory, 128 Kwords(DM: 32 Kwords,
EM: 32 Kwords×13 banks);
LD execution time, 0
CS1W-AD041-V102 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0.82A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables CS1W-AD041-V1 USER'S MANUAL. Name: Position Control Module.
Model: C200HW-NC113.
Control method: Open-loop, automatic trapezoid acceleration/deceleration.
Control output sig-nals: Pulse-train outputs.
Controlled axes: 1.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input CS1W-AD041-V1 USER'S MANUAL.
I/O type: B, E, J, K, N, R, S, T, ±80mV.
Conversion speed: 150 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CS1W-AD041-V1 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-AD041-V1 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.