Size: 35mm.
Type: 4 lines.
Lighting voltage: DC24V.
Color: blue.
Large tactile buttons and uniform lighting to create a general space.
Backlight brings a uniform, elegant and pleasant lighting.
Large tactile buttons are easier to touch.
Drive rod mechanism to keep the direction of the parallel button, even if the pressure on the side of the OMRON CS1W-AD161 Manual.
Damping mechanism to ensure high impact resistance
CS1W-AD161
A slim body with a thickness of 14.6 mm. Specifications: Optical ring (HPCF cable).Model: CPM2C-32EDT1C. Units with 32 I/O points
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.Name: e-CON Connector Type.
Specifications: Analog outputs;
2 outputs OMRON CS1W-AD161 Manual.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON CS1W-AD161 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. CPU Unit: CP1L-EM CPU Units with 40 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output(sourcing);
Inputs, 24; Output, 16.
Standards: CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: Set separately for each input.
Signal range; Resolution: 1 to 5 V (1/10,000),
0 to 10 V (1/20,000), -5 to 5 V (1/20,000),
-10 to 10 V (1/40,000), and 4 to 20 mA (1/10,000).
Conversion period: 20 μs/1 point, 25 μs/2 points,
30 μs/3 points, 35 μs/4 points,
The Direct conversion is provided.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.4% of F.S.
External connection: Reemovable terminal block CS1W-AD161 Safety Precautions.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 24V, --.
Standards: UC1, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analoog Input Units for converting analog input,
signals into binary data CS1W-AD161 Safety Precautions.
Analog Output Units for converting binary ,
data into analog output signals.