E32-D15YR type: standard type; soft (new standard),
Specialty: plane shape side,
Bending radius (mm): R; R1.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsAppearance: Vertical type.
Sensing method: Convergent reflective type.
Sensing distance: 2 to 5 mm E5AN-HSS2HH02BF-FLK User's Manual.
Output type: NPN output.
Output configuration: Light-ON
E5AN-HSS2HH02BF-FLK
Accurately detects objects placed in,
front of shiny Background.
A shiny background can be used as long as the distance between,
the sensor and the background is 20 mm or more.
Detects minute objects such as a 0.05-mm-dia. pure copper wire.
Small dispersion in sensing distance.
Light modulation effectively reduces external light interference E5AN-HSS2HH02BF-FLK User's Manual.
Wide operating voltage range: 5 to 24 VDC. Name: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485 E5AN-HSS2HH02BF-FLK User's Manual.
Input type: No input.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculatte the PID constants with the step,
response method E5AN-HSS2HH02BF-FLK Manual.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
Size: M12 (Brass); Single; Shielded.
Sensing distance: 5 mm.
Connectiing method (See note 1 E5AN-HSS2HH02BF-FLK Manual. ): M12 Connector.
Body length: Short.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications.