Insulation method: Phototriac.
Operation Display: Yes(green).
Output(SSR): AC.
Zero cross Function: NO.
Rated output Load: 2 A(at 100 to 240 VAC).
Rated input voltage (socket): 48 VAC/VDC, 100 VAC, 110 VAC, 200 VAC, 230 VAC.
Applicable model: G3RV-SR700/500-A AC/DC48V,G3RV-SR700/500-A AC100V,
G3RV-SR700/500-A AC110V, G3RV-SR700/500-A AC200V, G3RV-SR700/500-A AC230V GRT1-TS2P Manual.
Global standard size,
low profile slim I/O relay with width 6
GRT1-TS2P2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals GRT1-TS2P Manual.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal GRT1-TS2P Manual.
that is difficult to bend at the time of exchange. Name: Short-circuit Unit.
Current flow: 30 A, 40 A.
Applicable SSR: G3PA-430B-VD, G3PA-240B-VD.
Refer to Safety Precautions for All Solid State Relays.
Allows 2-wire Switching of 3-phase Power OMRON Analog I/O Units Manual.
Ideal for 2-wire switching of 3-phase heaters.
Improve ease of operation. Cable with connector (1 to 1) /G79-_C.
L size: 3000mm OMRON Analog I/O Units Manual.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Refer to Safety Precautions for All Solid State Relays.
Allows 2-wire Switching of 3-phase Power.
Ideal for 2-wire switching of 3-phase heaters OMRON Analog I/O Units Manual.
Improve ease of operation. Classification: electric arc barrier.Terminal (Wire connection): Push-In Plus Terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: DC, 12V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA uusing Au-plated GRT1-TS2P REFERENCE MANUAL.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed locatiion) GRT1-TS2P Manual.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging.