Action indicator: there are.
Applicable load of output: DC5 3A ~ 110V.
Input rated voltage: DC5 ~ 24V.
Insulation: photo coupler.
Zero trigger function: No.
Socket terminal type with same shape as MK type power relay.
New international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification GX-OD1618 Manual. (type -VD)
Socket terminal type of same size with MK (2 pole type)
GX-OD1618
A model with an action indicator to check the status of the input. Loose wire cable /G79-A_C.
L size: 2000mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Isolation method: Relay.
Zero cross function: No GX-OD1618 Manual.
Operation indicator: Yes.
Applicable output load(See note.): 5 A 100 to 240 VAC.
Rated input voltage: 12 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations GX-OD1618 Manual.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions OMRON Digital Temperature Controllers Manual.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays OMRON Digital Temperature Controllers Manual. Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC OMRON Digital Temperature Controllers Manual.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-pphase heaters GX-OD1618 INSTRUCTION MANUAL.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) GX-OD1618 Manual.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.