Standard certification: No.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC5V.
Insulation mode: three end two-way photoelectric switch.
Zero crossing trigger function.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type) GX-OD3228 INSTRUCTION MANUAL.
Achieved UL, CSA, EN (VDE certification) standard certification
GX-OD3228 (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input. Structure: single stable type.
Contact structure: 1a.
Structure: high flux protection.
Coil rated voltage: DC18V.
Voltage resistant 10kV 1 pole 3A open close small relay GX-OD3228 INSTRUCTION MANUAL.
High power electromagnetic loop is used to achieve high sensitivity (200mW).
Small relays, but can ensure the impact resistance of 10kV. Isolation: Phototriac.
Zero cross function: Yes.
Indicator: No.
Rated output load: 20 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model GX-OD3228 INSTRUCTION MANUAL.
Dedicated, compact aluminum PCB and power elements used.
Built-in varistor effectively absorbs external surges.
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV). Terminal (Wire connection): Push-In Plus Terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: DC, 24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA uusing Au-plated GX-OD3228 Manual.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed locatiion) GX-OD3228 Manual.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging.