Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: Yes (100 to 240 VAC only) H7CX-AW-G-N .
Control output: Contact (SPDT).
Operating mode: Down counting.
Max.counting speed: 5 kcps (see note 1
H7CX-AW-G-N).
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC H7CX-AW-G-N .
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator H7CX-AW-G-N .
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: Yes (100 to 240 VAC only).
Control output: Contact (SPDT).
Operating mode: Up counting.
Max.counting speed: 30 cps.
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC.
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Project: Japanese specification model.
Installation method: embedded installation.
All day control operation is simple
Can be carried out on the choice of a few weeks of action. (but only 1 of the week moves and all week specific dates can be set)
ON/OFF time setting has 24 steps.
Consistent with CE markers. Through the UL, CSA standard certification.
Rest day function can be easily carried out on holidays, such as the setting of a sudden break.
Test mode function can easilly confirm the program H7CX-AW-G-N User's Manual.
Can also be used to deal with a sudden change in the way of a semi automatic work.
The pulse action can cope with daylight saving time.
All models are equipped with finger protection function.
Producct series contains embedded installation, surface mount, the size of the agreement and other ways H7CX-AW-G-N User's Manual.
The same setting can be done with the timer action.