Product model: H7ET-NV-300
Name: Digital Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 6.85MB
Operation system: Time-limit operation, integrating operation.
Resetting system: Power-OFF resetting (excluding -M), external resetting,
manual resetting, automatic resetting.
No. of digits: 4 digits (switch-selectable):
0.01 to 99.99 s, 0.1 to 999.9 s, 1 to 9999 s, 0.1
to 999.9 min, 0.1 to 999.9 hrs, 1 to 9999 hrs,
1 s to 99 min 59 s, 1 min to 99 hrs 59 min H7ET-NV-300 Communications Manual.
Backup power supply function for memory protection: Can be,
enabled and disabled with a DIP switch H7ET-NV-300
DIN-sized (72 x 72 mm) Quartz Timer with,
Multiple Functions.
Wide time range from 1/100 seconds to 9999 hrs.
Built-in power supply incorporated in timer enables direct,
connection of sensors and other components.
Draw-out construction allows maintenance without,
disconnecting the wiring H7ET-NV-300 Communications Manual.
Power supply freely selectable within a range of 100 to 240 VAC;
a DC-operated version is also available.
Control outputs of both contact type and transistor type,
simultaneously available.
Seven operating modes (N, F, C, R, K, P, and Q) are available. Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0 H7ET-NV-300 Communications Manual. 1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A-2: Power ON Delay I, b: Repeat cycle 1,
E: Interval, Z: ON/OFF-duty-adjustable flicker, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1.
External connections: 8-pin socket.
Input: None.
Output: Contact output (time-limit SPDT + instantaneous SPDT),
Models with instantaneous contact outputs.
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry. Rated supply voltage: 100 to 240 VAC.
Resetting system (See note.): Electric resetting.
Control output: DPDT contact output,
(Time-limit output SPDT and instantaneous output SPDT).
Time range: 1 s to 60 h (60 s, 6 min, 60 min, 6 h, 60 h).
Large Setting Dial and Moving Pointers Ideal,
for Easy Operation and Monitoring.
Incorporating an easy-to-see large setting dial with moving pointers.
Wide time-setting range of 0.2 s to 60 h.
(available through three time-range model types).
Wide AC power supply range (100 to 240 VAC).
IP65 watertight and dust-tight front panel.
Approved by UL and CSA.
Conforms to EN61812-1 and IEC60664-1.
4 kV for Low Voltage, aand EMC Directives H7ET-NV-300 Manual.
Conforms to EMC standards.
Six-language instruction manual provided.
Programmable contact enables the building of a self-holding,
relay circuit as well as built-in instantaneous contact. (-NS).
Memory reteention (-NSR) H7ET-NV-300 Manual.
Finger protection terminal block.
Enables easy sequence checks through instantaneous outputs.
for a zero set value at any time range.
Related products
OMRON
Self-powered Time Counter
H7ET-NFV
OMRON Self-powered Time Counter H7ET-NFV
Timer input: AC/DC multi-voltage input 24 to
OMRON
Self-powered Time Counter
H7ET-N-B
OMRON Self-powered Time Counter H7ET-N-B
Timer input: No-voltage input. Display: 7-se
OMRON
Self-powered Time Counter
H7ET-N1
OMRON Self-powered Time Counter H7ET-N1
Timer input: No-voltage input. Display: 7-se
OMRON
Self-powered Time Counter
H7ET-NV1
OMRON Self-powered Time Counter H7ET-NV1
Timer input: PNP/NPN universal DC voltage inp