Brand: OMRON
Name: Self-powered Time Counter
Model: H7ET-N1
Timer input: No-voltage input.
Display: 7-segment LCD.
Time range: 999h59min59s ←→ 9999h59.9min(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m.

Supply voltage: 12 VDC.
Control output: Contact output, DPDT (time-limit DPDT,
or time-limit SPDT + instantaneous SPDT) Changed using a switch.
Four-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch OMRON H7ET-N1.
Sequence checks are easily performed by setting an instanta,
neous output to 0 H7ET-N1
Start signal control for the H3DK-M. Operation / reset system: time limit operation / auto reset.
Time limit contact: 4PDT.
Time range: 0.1s ~ 30min.
Supply voltage: AC110V, AC220V (50/60Hz); DC24V.
Mounting: surface /DIN guide rail mounting (with socket) OMRON H7ET-N1.
Micro timer compatible with MY relay.
ON delay function, can accurately control the time.
Large and transparent time setting knob is easy to set up time.
Pin configuration compatible with MY power relay.
Access to UL, CSA and CCC certification in line with EN61812-1 and EMC standards. Input type: DC voltage input type.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL) OMRON H7ET-N1.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table OMRON Self-powered Time Counter.
Action determine the color, can switch the green / Red 2 kinds of color display OMRON Self-powered Time Counter.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeInput type: DC voltage/current.
Supply voltage: 100 to 240 VAC.
Comparative Output Model: None OMRON Self-powered Time Counter.
Highly Visible LCD Display with 2-color,
(Red and Green) LEDs.
Multi-range DC voltage/current input.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Scaling, frront-panel forced-zero, zero-limit functions H7ET-N1.
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate).
Finger protective cover (standard equipment) guards against electric shock.
Water- and dust-pproof NEMA4X (IP66 equivalent) front panel OMRON H7ET-N1.
Recognized to U.S. and Canadian requirements under the Component,
Recognition Program of UL.
CE marking.